技術規(guī)格:
| 型 號 |
HFG-80 |
HFG-150 |
HFG-225 |
HFG-408 |
HFG-800 |
HLG-80 |
HLG-150 |
HLG-225 |
HLG-408 |
HLG-800 |
HTG-80 |
HTG-150 |
HTG-225 |
HTG-408 |
HTG-800 |
|
內 尺 寸(mm) |
W |
400 |
500 |
500 |
600 |
1000 |
400 |
500 |
500 |
600 |
1000 |
400 |
500 |
500 |
600 |
1000 |
| H |
500 |
600 |
750 |
850 |
1000 |
500 |
600 |
750 |
850 |
1000 |
500 |
600 |
750 |
850 |
1000 |
| D |
400 |
500 |
600 |
800 |
800 |
400 |
500 |
600 |
800 |
800 |
400 |
500 |
600 |
800 |
800 |
|
外 尺 寸(mm) |
W |
930 |
1030 |
1080 |
1170 |
1600 |
930 |
1030 |
1080 |
1170 |
1600 |
930 |
1030 |
1080 |
1170 |
1600 |
| H |
1310 |
1410 |
1620 |
1720 |
1870 |
1310 |
1410 |
1620 |
1720 |
1870 |
1310 |
1410 |
1620 |
1720 |
1870 |
| D |
810 |
910 |
1120 |
1320 |
1320 |
810 |
910 |
1120 |
1320 |
1320 |
810 |
910 |
1120 |
1320 |
1320 |
| 容積(L) |
80 |
150 |
225 |
408 |
800 |
80 |
150 |
225 |
408 |
800 |
80 |
150 |
225 |
408 |
800 |
| 溫度范圍 |
-20℃~150℃ |
-40℃~150℃ |
-70℃~150℃ |
| 升溫速度 |
-20℃~100℃約35min |
-40℃~100℃約45min |
-70℃~100℃約60min |
| 降溫速度 |
20℃~-20℃約45min |
20℃~-40℃約60min |
20℃~-70℃約90min |
| 溫度分布均度 |
±0.5℃ |
±1℃ |
±0.5℃ |
±1℃ |
±0.5℃ |
±1℃ |
| 濕度分布均度 |
±3% |
±5% |
±3% |
±5% |
±3% |
±5% |
| 冷凍系統(tǒng) |
單段式、全密閉式壓縮機,氣冷式/水冷式 |
二段式、全密閉式壓縮機,氣冷式/水冷式 |
| 濕度范圍 |
20%~98%RH(可根據客戶要求定做:低濕型可達到5%RH) |
| 溫度穩(wěn)定度 |
±0.3℃ |
| 濕度穩(wěn)定度 |
±2.5%RH |
| 內部材質 |
SUS-304#不銹鋼(或一級鏡面光板) |
| 外部材質 |
高級耐磨烤漆涂裝(或SUS-304#不銹鋼) |
| 保溫材質 |
巖棉及硬質PU發(fā)泡保溫 |
| 加濕系統(tǒng) |
表面蒸發(fā)式,附加缺水斷電及超濕保護 |
| 供水系統(tǒng) |
內置純水生成裝置,不經人工加水,可直接自來水,并附缺水警示裝置 |
| 保護裝置 |
無熔絲開關,壓縮機過載、冷媒高、超溫、超濕斷電、缺水保護開關、溫度極限保護及故障警報裝置 |
| 標準配件 |
自動除霧玻璃視窗,上下可調隔層兩片,測試孔、操作室內燈,移動輪 |
| 溫濕度調節(jié) |
平衡調溫調濕方式 |
| 加熱系統(tǒng) |
不銹鋼散熱式加熱器 |
| 除濕系統(tǒng) |
冷凍潛熱除濕方式 |
| 電 源 |
AC220V/380V±10%,1PH,50/60Hz |
| 符合標準 |
GB、ISO、ASTM、UL、CEN…… |